Pit & Pendulum
Real-time IoT energy monitoring & optimisation was deployed across 6 categories of equipment over a representative measurement period of one week.
8 units optimised
4 units optimised
1 unit optimised
1 unit optimised
1 unit optimised
GeoEnergy's assessment combined physical site intelligence with live IoT monitoring data across all connected equipment at the Pit & Pendulum .
Physical survey of Pit & Pendulum capturing equipment inventory, scheduling practices, and operational behaviours across 16 items.
Half-hourly electricity and gas consumption data reviewed
Out-of-hours usage reviewed against actual trading hours
Bottle fridges, beerline & cask coolers, soft drink coolers, cellar cooling, boiler and outdoor lighting — the principal sources of controllable energy consumption at this site.
38,805 kWh annualised savings potential
Mixed rate: gas @ £0.06/kWh, electricity @ £0.23/kWh
The boiler out-of-hours is the single largest saving at 23,3 kWh/yr, followed by beerline coolers at 4,9 kWh/yr.
All figures are annualised from one week of live monitoring data.
Savings are achieved by controlling when equipment runs — turning things off overnight and during closed hours, with smart pre-starts to ensure everything is ready for trading.
Sites to be selected to represent a cross-section of estate typologies — ensuring findings are broadly applicable at rollout.
Confirm that half-hourly data analysis translates into measurable, on-bill cost reduction at live sites
Surface site-specific behaviours and equipment issues beyond those visible through desktop analysis alone
Produce an evidenced commercial case — with verified payback metrics — to support a board-level decision on full deployment
This section outlines the technical approach to energy monitoring and optimisation. IoT sensors were deployed on each identified equipment type, logging consumption data at minute intervals. Advanced algorithms analysed usage patterns, identified inefficiencies, and simulated optimised schedules based on operational hours and thermal inertia. Environmental factors were cross-referenced to ensure accurate baseline calculations.
Understanding the core terms used in this report:
Daily Baseline
Total all equipment
Projected Baseline Cost
Electricity £9,750 + Gas £1,996
Projected Optimised Cost
Electricity £6,073 + Gas £627
Annualised Saving
Projected at mixed rate
* Boiler & hot water calculated at gas rate (£0.06/kWh). All refrigeration at electricity rate (£0.23/kWh). Hot water saving pending gas meter confirmation.
The charts below show examples of live energy consumption data captured over the measurement week. Spikes visible during the optimised period are due to brief overshoot when equipment powers on — this is expected behaviour.

INTERIM POV ENERGY OPTIMISATION UPDATE